Mobile Metal Shielded Rubber Sheathed Flexible Cable with Rated Voltage of 1.9/3.3kV

零售价
0.0
市场价
0.0
浏览量:
1000
产品编号
数量
-
+
库存:
所属分类
Back to list
1
Details
[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[[产品参数, 参数]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]]

Scope of application
This product is suitable for power connection of mobile coal mining equipment in underground mines with rated voltage of 1.9/3.3kV.

Executive standard
MT818.1-2009 Cables for Coal Mines Part 1: General requirements for mobile flexible cables for coal mines.
MT818.7-2009 Coal Mine Cable Part 6: Mobile shielded flexible cable with rated voltage 6/10kV and below.

Features
The conductor of the cable adopts the same twisted structure to improve the flexibility of the cable and reduce the outer diameter of the cable; the power core insulation adopts XJ-30A EPDM rubber insulation; the outer sheath adopts self-developed flame retardant The formula and the flame retardant grade meet the requirements of the MT386-2011 "Test Methods and Judgment Rules for Flame Retardant Cables for Coal Mines". The use of the above materials and technologies ensures the safety and reliability of cable operation.

Cable model, name, purpose

Model

Name

Use

MYPT-1.9/3.3

Mobile metal shielded rubber sheathed flexible cable for coal mine

Power connection of mobile coal mining equipment in underground mine with rated voltage 1.9/3.3kV.

Cable working conditions
1. The rated voltage Uo/U is 1.9/3.3kV.
2. The minimum bending radius of the cable is 6 times the cable diameter.
3. The ground core of the cable must be well grounded.
4. Frequency voltage test

The insulated power core can withstand the power frequency voltage test specified in Table 7 without being broken down.

Table 7

Insulated core type

Rated voltage Uo/U, kV

Test voltage (effective value), kV

Time of applying voltage, min

Power cord

1.9/3.3

6.8

5

Cable structure diagram

Cable structure diagram

1. Power core conductor; 2. Insulation; 3. Metal shield (also used as ground core); 4. Sheath

扫二维码用手机看
未找到相应参数组,请于后台属性模板中添加

MOBILE SITE

QR Code

CONTACT US 

TEL:+86-635-6554666 , 6554066

FAX:+86-635-6550777

PHONE:+86-18906358051 / +86-15306352001

Service Hotline:+86-400-0635-579

Mailbox:yghhdl@163.com

 

ONLINE MESSAGE 

留言应用名称:
客户留言
描述:
验证码

Copyright © 2020  Shandong Yanggu Haohui Cable Co., Ltd.       鲁ICP备13011977号      Power by: 300.cn