- Product Description
-
- Commodity name: PVC insulated wire and cable with rated voltage of 450 750V and below
- Commodity ID: 1171377279184031744
Scope of application
Suitable for DC or AC 50HZ, rated voltage 450/750V and below power, household appliances, instrumentation, telecommunications equipment and lighting lines fixed laying and mobile laying cables.Use characteristics and main electrical performance indicators
1. Cable rated voltage U0/U is divided into 450/750V, 300/300, 300/500V;
2. The long-term working temperature of the cable conductor shall not exceed 70 ℃;
3. The cable laying environment shall not be lower than 0 ℃;
4. Water test voltage: rated voltage 450/750V:2500V/5min insulation does not break down; Rated voltage 300/300V:2000V/5min insulation does not break down; Rated voltage 300/500V:2000V/5min insulation does not break down.
Minimum bending radius of cable: the bending radius of cable diameter less than 25mm and below shall not be less than 4D(D cable diameter); The bending radius of cable diameter 25mm and above shall not be less than 6D(D cable diameter);
6. The cable shall meet the relevant technical indexes and requirements of GB/T5023-2008 "PVC insulated cables with rated voltage of 450/750V and below" and JB/T8734-2016 "PVC insulated cables and flexible cords with rated voltage of 450/750V and below.Cable model name
Model
Name
Number of cores
Production range mm2
Rated voltage V
Executive standard
60227IEC01(BV)
General purpose single core hard conductor unsheathed cable
1
1.5-400
450/750
GB/T5023.3
60227IEC02(RV)
General purpose single-core flexible conductor unsheathed cable
1
1.5-240
450/750
60227IEC05(BV)
Single-core solid conductor unsheathed cable with conductor working temperature 70 ℃ for internal wiring
1
0.5-1.0
300/500
60227IEC06(RV)
Single-core soft conductor unsheathed cable with conductor working temperature of 70 ℃ for internal wiring
1
0.5-1.0
300/500
60227IEC07(BV-90)
Single-core solid conductor unsheathed cable with conductor working temperature of 90 ℃ for internal wiring
1
0.5-2.5
300/500
60227IEC08(RV-90)
Single-core soft conductor unsheathed cable with conductor working temperature of 90 ℃ for internal wiring
1
0.5-2.5
300/500
60227IEC10(BVV)
Light PVC sheathed cable
2~5
1.5-35
300/500
GB/T5023.4
60227IEC52(RVV)
Light PVC sheathed flexible cord
2 to 3
0.5-0.75
300/300
GB/T5023.5
60227IEC53(RVV)
Ordinary PVC sheathed flexible cord
2~5
0.75-2.5
300/500
BV
Copper conductor PVC insulated wire
1
0.75-1.0
300/500
JB/T8734.2
BLV
Aluminum core PVC insulated wire
1
2.5-400
450/750
BVR
Copper conductor PVC insulated flexible wire
1
2.5-70
450/750
JB/T8734.2
BVV
Copper conductor PVC insulated and sheathed round cable
1
0.75-10
300/500
BLVV
Aluminum conductor PVC insulated and sheathed round cable
1
2.5-10
300/500
BVVB
Copper conductor PVC insulated and sheathed flat cable
2 to 3
0.75-10
300/500
BLVVB
Aluminum conductor PVC insulated and sheathed flat cable
2 to 3
0.75-10
300/500
RVS
Copper conductor PVC insulated stranded connection flexible cable
2
0.5~6
300/300
JB/T8734.3
RVB
Copper conductor PVC insulated flat type unsheathed flexible cable
2
0.5~6
300/300
RVV
Copper conductor PVC insulated PVC sheathed flexible cable
2~41
0.5~10
300/500
RVVP
Copper conductor PVC insulated shielded PVC sheathed flexible cable (wire)
1 to 16
0.5~2.5
300/300
JB/T8734.5
Flame-retardant and fire-resistant wire
Current Flame Retardant and Fire Resistant Wire Model
Series code
Code
Name
Flame retardant series
ZA
ZB
ZC
ZDFlame Retardant Class A
Flame retardant Class B
Flame Retardant Class C
Flame Retardant Class DRefractory series
N
ZAN
ZBN
ZCN
ZDNFire resistance
Flame Retardant Class A Fire Resistant
Flame Retardant Class B Fire Resistant
Flame Retardant Class C Fire Resistant
Flame Retardant Class D Fire ResistantThe performance of flame-retardant and fire-resistant wires shall meet the requirements of GB/T19666-2019.
Wire physical map

Next article
Next article