Rated voltage 1.9/3.3kV and below shearer shielding monitoring reinforced flexible cable


Key words:



  • Product Description
    • Commodity name: Rated voltage 1.9/3.3kV and below shearer shielding monitoring reinforced flexible cable
    • Commodity ID: 1171377244660715520

    1. Scope of application
    This product is suitable for the power connection of shearers and similar equipment with rated voltage Uo/U of 1.9/3.3kV and below.

    2. Implementation of standards
    MT818.1-2009 coal mine cables-Part 1: General provisions for flexible mobile fire-retardant cables for coal mines.
    Cables for MT818.3-2009 coal mines-Part 3: Shielding monitoring reinforced flexible cables for shearers with rated voltage of 1.9/3.3kV and below.

    3. Features
    The conductor of the cable adopts the same direction structure, which not only improves the bendability of the cable, but also reduces the outer diameter of the cable. XJ-30A ethylene-propylene insulating rubber is used for power wire core insulation. The metal fiber braided reinforcement layer is used outside the power wire core to improve the mechanical properties of the cable. The outer protective layer is made of XH-21A chloroprene rubber, and the flame retardant grade meets the requirements of the MT386-2011 "Test Methods and Judgment Rules for Flame Retardancy of Flame Retardancy of Flame Retardancy of Flame Retardant Cables.

    4. Cable model name

    Model

    Name

    Specification mm2

    MCPJB-0.66/1.14

    Shearer shielding monitoring braided reinforced rubber sheathed flexible cable

    Power connections for shearers and similar equipment for rated voltages up to 0.66/1.14kV. Cable can be directly towed for use

    MCPJB-1.9/3.3

    Shearer shielding monitoring braided reinforced rubber sheathed flexible cable

    Power connections for shearers and similar equipment up to rated voltage 1.9/3.3kV. Cable can be directly towed for use

    MCPJR-0.66/1.14

    Shearer shielding monitoring winding reinforced rubber sheathed flexible cable

    Power connections for shearers and similar equipment for rated voltages up to 0.66/1.14kV. But the cable must be used in the protective chain plate

    MCPJR-1.9/3.3

    Shearer shielding monitoring winding reinforced rubber sheathed flexible cable

    Power connections for shearers and similar equipment for rated voltages up to 0.66/1.14kV. But the cable must be used in the protective chain plate

    5. Cable working conditions
    5.1 rated voltages Uo/U are 0.66/1.14kV and 1.9/3.3kV respectively.
    The minimum bending radius of the 5.2 cable is 6 times the cable diameter.
    The earth core of the 5.3 cable shall be well grounded.

    6. Cable structure diagram

    额定电压1.9/3.3kV及以下采煤机屏蔽监视加强型软电缆

    7. Power frequency voltage test
    The insulated power core and control core shall be subjected to the power frequency voltage test specified in Table 5 without breakdown.

    Table 5 Power frequency test voltage

    Type of insulated core

    Rated voltage kV

    Test voltage (effective value) kV

    Effective value of applied voltage min

    Power line core

    1.9/3.3

    6.8

    5

    0.66/1.14

    3.7

    Control core

    -

    1.5

    5