Metal shielded rubber sheathed flexible cable for shearer with rated voltage of 1.9/3.3kV and below
Key words:
Classification:
- Product Description
-
- Commodity name: Metal shielded rubber sheathed flexible cable for shearer with rated voltage of 1.9/3.3kV and below
- Commodity ID: 1171377247374430208
1. Scope of application
This product is suitable for the power connection of shearers and similar equipment with rated voltage Uo/U of 1.9/3.3kV and below.2. Implementation of standards
MT818.1-2009 coal mine cables-Part 1: General provisions for flexible mobile fire-retardant cables for coal mines.
Cables for MT818.4-2009 coal mines-Part 4: Metal shielded flexible cables for shearers with rated voltage of 1.9/3.3KV and below.3. Features
The conductor of this cable adopts the same direction structure, which not only improves the bendability of the cable, but also reduces the outer diameter of the cable. XJ-30A ethylene-propylene insulating rubber is used for power wire core insulation. The metal fiber braided reinforcement layer is used outside the power wire core to improve the mechanical properties of the cable. The outer protective layer is made of XH-03A neoprene, and the flame retardant grade meets the requirements of the MT386-2011 "Test Methods and Judgment Rules for Flame Retardancy of Flame Retardancy of Flame Retardant for Flame Retardant for Flame, ensure the safety and reliability of cable operation.4. Cable model, name and purpose
Model
Name
Use
MCPT-0.66/1.14
Shearer metal shield rubber sheathed flexible cable
Power connection for shearers and similar equipment with rated voltage of 0.66/1.14kV
MCPTJ-0.66/1.14
Shearer metal shield rubber sheathed flexible cable
Power connection for shearers and similar equipment with rated voltage of 0.66/1.14kV
MCPT-1.9/3.3
Shearer metal shield rubber sheathed flexible cable
Power connection for shearers and similar equipment with rated voltage of 1.9/3.3kV and below
MCPTJ-1.9/3.3
Shearer metal shield rubber sheathed flexible cable
Power connection for shearers and similar equipment with rated voltage of 1.9/3.3kV and below
5. Cable structure diagram
MCPT-0.66/1.14 MCPT-1.9/3.3 MCPTJ-0.66/1.14 MCPTJ-1.9/3.3
1-power line core conductor; 2-power line core insulation; 3-metal/fiber braided shield; 4-ground line core conductor; 5-auxiliary line core conductor;
6-Control core conductor; 7-Auxiliary core insulation; 8-Control core insulation; 9-Control core cladding; 10-Outer sheath6. Cable working conditions
6.1 rated voltages Uo/U are 0.66/1.14kV and 1.9/3.3kV respectively.
The minimum bending radius of the 6.2 cable is 6 times the cable diameter.
The earth core of the 6.3 cable shall be well grounded.7. Power frequency test voltage
The insulated power core and control core shall be subjected to the power frequency voltage test specified in Table 6 without breakdown.Table 6
Type of insulated core
Rated voltageUo/U(KV)
Test voltage (effective value) kV
Voltage application time (min)
Power line core
0.66/1.14
1.9/3.33.7
6.85
Control core
1.5
5