PRODUCTS CENTER
Metal Shielded Rubber Sheathed Flexible Cable of Shearer with Rated Voltage of 1.9/3.3kV and Below
1. Scope of application
This product is suitable for power connection of shearers and similar equipment with rated voltage Uo/U of 1.9/3.3kV and below.
2. Implementation standards
MT818.1-2009 Cables for coal mines Part 1: General requirements for mobile flame-retardant flexible cables for coal mines.
MT818.4—2009 Coal Mine Cable Part 4: Rated voltage 1.9/3.3KV and below coal mining machine metal shielded flexible cable.
3. Features
The conductor of this cable adopts the same direction structure to improve the flexibility of the cable and reduce the outer diameter of the cable; the power core insulation adopts XJ-30A ethylene-propylene insulating rubber; the power core adopts a metal fiber braided layer to improve the cable Mechanical properties; XH-03A neoprene rubber is used for the outer sheath, and the flame retardant grade meets the requirements of the MT386-2011 "Test Methods and Judgment Rules for Flame Retardant Cables for Coal Mines". The use of the above materials and technologies guarantees The safety and reliability of cable operation.
4. Cable type, name and purpose
Model |
Name |
Use |
MCPT-0.66/1.14 |
Shearer metal shielded rubber sheathed flexible cable |
Power connection of coal shearer and similar equipment with rated voltage of 0.66/1.14kV |
MCPTJ-0.66/1.14 |
Shearer metal shielded rubber sheathed flexible cable |
Power connection of coal shearer and similar equipment with rated voltage of 0.66/1.14kV |
MCPT-1.9/3.3 |
Shearer metal shielded rubber sheathed flexible cable |
Power connection of shearer and similar equipment with rated voltage of 1.9/3.3kV and below |
MCPTJ-1.9/3.3 |
Shearer metal shielded rubber sheathed flexible cable |
Power connection of shearer and similar equipment with rated voltage of 1.9/3.3kV and below |
5. Cable structure diagram
MCPT—0.66/1.14 MCPT—1.9/3.3 MCPTJ—0.66/1.14 MCPTJ—1.9/3.3
1- power core conductor; 2- power core insulation; 3- metal/fiber braided shield; 4- ground core conductor; 5- auxiliary core conductor;
6-control core conductor; 7-auxiliary core insulation; 8-control core insulation; 9-control core coating; 10-outer sheath
6. Cable working conditions
6.1 The rated voltage Uo/U is 0.66/1.14kV and 1.9/3.3kV respectively.
6.2 The minimum bending radius of the cable is 6 times the cable diameter.
6.3 The ground core of the cable should be well grounded.
7. Power frequency test voltage
The insulated power core and control core are subjected to the power frequency voltage test specified in Table 6 without being broken down
Table 6
Insulated core type |
Rated voltage Uo/U (kV) |
Test voltage (effective value) kV |
Applied voltage time (min) |
Power cord |
0.66/1.14 |
3.7 |
5 |
Control core |
|
1.5 |
5 |