VLV0.6/1kV PVC insulated power cable
This product is suitable for distribution network, industrial devices and other fields for fixed laying in the AC 50HZ, rated voltage 0.6/1kV power transmission line, transmission of electrical energy.
Key words:
Classification:
- Product Description
-
- Commodity name: VLV0.6/1kV PVC insulated power cable
This product is suitable for distribution network, industrial devices and other fields for fixed laying in the AC 50HZ, rated voltage 0.6/1kV power transmission line, transmission of electrical energy.
Scope of application
This product is suitable for distribution network, industrial devices and other fields for fixed laying in the AC 50HZ, rated voltage 0.6/1kV power transmission line, transmission of electrical energy.Executive standard
This product GB/T12706 "rated voltage 1kV(Um = 1.2kV) to 35kV(Um = 40.5kV) extruded insulated power cable", GB/T12706.1 part I: rated voltage 1.2kV(Um = 7.2kV) and 3kV(Um = 3.6kV).Use Features
1. Allowable long-term working temperature of cable conductor:Maximum conductor temperature of various insulation mixture cables
insulating mixture
Maximum conductor temperature ℃
Normal operation
Short circuit (maximum duration 5S)
Polyvinyl chloride (PVC/A)
Conductor cross-sectional area ≤ 300mm2
Conductor cross-sectional area> 300mm2
Cross-linked polyethylene (XLPE)70
70
90160
140
2502. The ambient temperature during cable laying shall not be lower than 0 ℃
3. Minimum allowable bending radius for cable laying:Minimum allowable bending radius for cable laying
Project
single core cable
multi-core cable
Minimum bending radius of cable at installation
No Armored
armored
No Armored
armored
20D
15D
15D
12D
Note: D is the outer diameter of the cable
4. The rated voltage of the cable U0/U(Um) is 0.6/1(1.2)kV and 1.8/3(3.6)kV
U0: Rated power frequency voltage between conductor to ground or metal shield for cable design;
U: Rated power frequency voltage between conductors for cable design;
Um: The maximum value of the "maximum system voltage" that the device can withstand.routine test
Rated voltageU0(KV)
Test voltage kV
0.6
1.83.5
6.5Duration 5min No breakdown of insulation
Common cable model
Model
Name
COPPER CORE
Aluminum core
YJV
YJY
YJV22
YJV23
YJV32
YJV33YJLV
YJLY
YJLV22
YJLV23
YJLV32
YJLV33XLPE insulated PVC sheathed power cable
XLPE insulated PE or polyolefin sheathed power cable
XLPE insulated steel tape armored PVC sheathed power cable
XLPE insulated steel tape armored PE or polyolefin sheathed power cable
XLPE insulated fine round steel wire armored PVC sheathed power cable
XLPE insulated fine round steel wire armored PE or polyolefin sheathed power cableVV
VY
VV22
VV23
VV32
VV33VLV
VLY
VLV22
VLV23
VLV32
VLV33PVC insulated PVC sheathed power cable
PVC insulated PE or polyolefin sheathed power cable
PVC insulated steel tape armored PVC sheathed power cable
PVC insulated steel tape armored polyethylene or polyolefin sheathed power cable
PVC insulated fine round steel wire armored PVC sheathed power cable
PVC insulated fine round steel wire armored polyethylene or polyolefin sheathed power cableFlame retardant characteristics are not included in the model in the table
The current product combustion characteristics code
Series code
Code
Name
Flame retardant series
halogen
ZA
ZB
ZC
ZDFlame Retardant Class A
Flame retardant Class B
Flame Retardant Class C
Flame Retardant Class DHalogen-free low smoke
WDZ
THE WILL
WDZB
THE WIDE
WDZDHalogen-free low smoke flame retardant
Halogen-free low-smoke flame retardant Class A
Halogen-free low-smoke flame retardant Class B
Halogen-free low-smoke flame retardant Class C
Halogen-free low-smoke flame retardant Class DRefractory series
halogen
N
ZAN
ZBN
ZCN
ZDNFire resistance
Flame Retardant Class A Fire Resistant
Flame Retardant Class B Fire Resistant
Flame Retardant Class C Fire Resistant
Flame Retardant Class D Fire ResistantHalogen-free low smoke
WDZN
CONTINUATION
ALLEGES
WDZCN
THE LADYHalogen-free low-smoke flame-retardant and fire-resistant
Halogen-free low-smoke flame retardant Class A fire-resistant
Halogen-free low-smoke flame retardant Class B fire-resistant
Halogen-free low smoke flame retardant Class C fire resistance
Halogen-free low smoke flame retardant Class D fire resistanceThe performance of flame retardant and halogen-free low smoke cable meets the requirements of GB/T19666-2019.
Cable structure diagram and physical drawing
Yanggu Haohui cable main models are: VV, VLV, VY, VLY, VV22, VLV22, VV23, VLV23, VV32, VV33, VLV33, VV42, VLV43, VLV43, YJV, YJLV, YJY, YKLY, YJV22, VLV23, VLV23, VVV32, VVVV32, YKR, KVVRP, KYJV, KYJVR, KYJY, KYJYR, KYJV22, KYJV23, KYJVP, KYJVP2, KYJYRP and other commonly used series products, BV series products.
Yanggu Cable,Yanggu cable manufacturers,Yanggu Power Cable,Mineral insulated fireproof cable,Coal Mine Cable,Aluminum alloy cableShandong Yanggu Haohui Cable Co., Ltd.Website:www.yghhdl.comTelephone: 0635-6554666, 6554066Contact: Manager Zhang15306352001national service hotline: 400-0635-579Key words:- 电力电缆